qiao@hvtest.cc15871365102
  • เครื่องทดสอบ TTR ของหม้อแปลงไฟฟ้า UHV-332

    UHV-332 transformer Turns Ratio Tester Suitable for transformer testing of three-phase transformer, z-winding transformer, rectifying transformer and railway electrical system

    รายละเอียดสินค้าของเครื่องทดสอบ TTR ของหม้อแปลง UHV-332


    Product Introduction




    พารามิเตอร์ผลิตภัณฑ์

    Ratio Measure Range

    0.910000

    Measure speed

    Complete three-phase test within 35 seconds

    ความแม่นยำในการวัด

     

     

     

     

     

     

     

     

    The measurement accuracy of high-voltage side voltage is 0.05%

    The measurement accuracy of low-voltage side voltage is 0.1%

    Phase angle resolution: 0.01 °

    Phase angle measurement accuracy: 0.1 °

    Turns ratio resolution: 0.0001

    Turns ratio measurement accuracy

    0.1%0.9200

    0.2%2002000

    0.3%200010000

    According to user requirements, equipment with a full range of 0.1 level can be customized

    แรงดันขาออก

    Test ordinary transformer AC25V and test low input voltage transformer AC5V

    Portable

    Suitable for field work

    ขนาดโดยรวม

    320mm (length) X 240mm (width) X 130mm (height)

    น้ำหนัก

    2.6kg


    Product features

    1. True three-phase testing: single-phase power input, internal digital synthesis of three-phase standard sine wave signal source, through high fidelity power amplifier, generates three-phase test power output (distortion less than 0.1%, symmetry better than 0.05%), the test results have better equivalence, and there will be no group misjudgment or other phenomena.

    2. Powerful function: It can perform single-phase measurement and automatic testing of three-phase windings. Both single-phase and three-phase can measure polarity and phase angle. It can complete the measurement of AB, BC, CA three-phase transformation value, phase angle value, error, tap position, tap value and other parameters in one go, and can automatically identify the group number (0-11 is equivalent to 1-12).

    3. Phase angle measurement function: Accurately measure the phase angle (0-360 °) between the high and low voltage sides, and can measure the transformation ratio and angle of non integer point transformers.

    4. Hexagonal diagram display function: The test results are displayed in numerical and hexagonal vector diagrams, which intuitively show the connection group of the transformer.

    5. Blind testing function: No need to select the wiring method or wiring group, measuring Y/△ and △/Y transformers does not require external short circuiting, and the wiring method can be automatically switched according to the selected testing content. It is entirely possible to measure the transformation ratio and group number of transformers without nameplates.

    6. Tap test: It can quickly measure the transformation ratio and transformation ratio error at each tap switch position. The rated transformation ratio only needs to be input once, and the transformation ratio error at each tap position can be calculated without repeated input.

    7. At the same time, it has two functions: measuring the turns ratio and measuring the operating voltage transformation ratio. The operating transformation ratio can more accurately reflect the actual value of the voltage transformation ratio of the transformer in actual operation.

    8. It has a specialized testing function for low input voltage transformers. For transformers with very low primary voltage, a special voltage is used for testing to avoid situations where the excitation current is too large to test.

    9. Good anti vibration performance: The use of military connectors enhances the anti vibration performance.

    10. Good anti vibration performance: The use of military connectors enhances the anti vibration performance.

    11. Adopting a 7-inch high-definition true color LCD screen, the display of data and vector graphics is intuitive and delicate.

    12. The instrument comes with a thermal sensitive high-speed micro printer, which can print and retain the test results at any time.

    13. The instrument has a USB interface and can support USB drives to copy stored data files to a computer. (The data file is in text format and does not require specialized software to open)

    14. The test source used in this instrument is a standard sine digital source synthesized digitally, with a distortion of less than 0.1%, and is not affected by the quality of the working power supply.

    15. Convenient to carry: small size and light weight.

    16. Equipped with high-capacity lithium-ion rechargeable batteries internally, the testing work can be completed on site without any power supply. With one full charge, it can perform more than 500 consecutive measurements.


    Factors Affecting the Accuracy of Transformer Turns Ratio Testing

    Wiring error: If the wiring is not standardized, it can easily lead to reading deviation.

    External interference: Electromagnetic interference on site may affect the accuracy of the test signal.

    The accuracy of the equipment itself: The accuracy of the testing instrument directly determines the reliability of the results.

    Transformer temperature: Temperature changes can sometimes have a small impact on the winding parameters of transformers.


    Product Applications

    1. Transformer Manufacturing and Production

    Quality Control: During the production of semi‑finished and finished transformers, the transformer turns ratio tester is used to accurately measure the turns ratio to ensure compliance with design requirements. This helps identify and correct potential issues at the manufacturing stage, thereby improving product quality.

    Efficiency Improvement: By using the transformer turns ratio tester, manufacturers can save substantial time and labor costs, thus increasing production efficiency. The tester can automatically complete the testing process and quickly provide accurate results, reducing the time required for manual operations and judgment.

    2. Power Systems

    Power Testing: In power systems, the transformer turns ratio tester is widely used in electrical testing. By performing turns ratio tests on transformers, it ensures their normal operation and prevents power accidents caused by incorrect turns ratios.

    Equipment Maintenance: Transformers in power systems require regular maintenance and overhaul. The tester helps maintenance personnel promptly detect the turns ratio, identify potential issues, and take corrective actions, thereby ensuring stable operation of the power system.

    3. Other Industries

    Railway Systems: In railway systems, the transformer turns ratio tester is used to test railway electrification equipment, ensuring its normal operation and safety.

    Petrochemical Industry: In the petrochemical industry, the tester is applied to test petrochemical equipment, safeguarding normal operation and production safety.

    New Energy Industry: In new energy sectors such as wind power and solar power generation, the transformer turns ratio tester is used to test renewable energy equipment, ensuring proper operation and stable energy supply.


    Frequently Asked Questions (FAQ)

    Q1: Why is a turns ratio test necessary for transformers?
    A1: The turns ratio is a fundamental parameter of a transformer. Testing it can determine whether the transformer windings are correctly connected and whether faults such as inter‑turn short circuits exist.

    Q2: How can electromagnetic interference be avoided during on‑site testing?
    A3: It is advisable to perform the test on the low‑voltage side of the transformer whenever possible, use well‑shielded test cables, and ensure that the testing instrument itself has adequate anti‑interference capability.

    Q3: What are the advantages of the turns ratio testers manufactured by Wuhan UHV Power Technology Co., Ltd.?
    A4: The equipment from Wuhan UHV Power Technology Co., Ltd. is renowned for its high accuracy, full automation, ease of operation, powerful data management functions, and comprehensive after‑sales service.

    Q4: Besides the turns ratio test, what other important transformer tests are there?
    A5: Common additional tests include insulation resistance testing, dielectric loss testing, winding resistance testing, and no‑load/load tests.












    คุณอาจจะชอบ

    • มีคำถามใดๆ!

      อย่าลังเลที่จะติดต่อเราได้ตลอดเวลา
      ติดต่อเรา
    • เยี่ยมชมเรา

      อาคาร 6, สวนอุตสาหกรรมเครื่องกลออพติกส์แวลลีย์, 84 ถนน Gaoxin 5,
      เขตพัฒนาเทคโนโลยีใหม่ทะเลสาบตะวันออก เมืองหวู่ฮั่น มณฑลหูเป่ย ประเทศจีน

    • ส่งอีเมลถึงเรา

      qiao@hvtest.cc

    • โทรหาเรา

      +86-15871365102